SEALING CABINET TO FLOOR

Step A - Position Cabinet
When positioning cabinet into a final location make sure there

are no obstructions in front of the intake and exhaust areas.

These areas are located in the front and back of the cabinet.
Step B - Level Cabinet
Cabinet should be level, side to side and front to back. Place a

carpenter’s level in the interior floor in four places:

1. Position level in the inside floor of the unit near the front.

(Level should be parallel to cabinet front). Level cabinet.

2. Position level at the inside rear of cabinet. (Again level

should be placed parallel to cabinet back).

3. Perform similar procedures to steps a & b by placing the

level on inside floor (left and right sides - parallel to the

depth of the freezer). Level cabinet.

Step C

Draw an outline on the base on the floor.
Step D

Raise and block the front side of the cabinet.
Step E

Apply a bead of “NSF Approved Sealant”, (see list below),

To floor half inch inside the outline drawn. The bead must

be heavy enough to seal the entire cabinet surface when it is

down on the sealant.

Step F

Raise and block the rear of the cabinet.
Step G

Apply sealant on floor as outline in Step E. on other three

sides.
Step H

Examine to see that cabinet is sealed to floor around

entire perimeter.
NOTE

Asphalt floors are very susceptible to chemical attack. A layer of

tape on the floor prior to applying the sealant will protect the floor.

NSF Approved Sealants:
1. Minnesota Mining #ECU800 Caulk

2. Minnesota Mining #ECU2185 Caulk

3. Minnesota Mining #ECU1055 Bead

4. Minnesota Mining #ECU1202 Bead

5. Armstrong Cork - Rubber Caulk

6. Products Research Co. #5000 Rubber Caulk

7. G.E. Silicone Sealer

8. Dow Corning Silicone Sealer

VENTILATION

A.

Set unit in its final location. Be sure there is adequate

ventilation in your room. Maximum ambient

operating temperature is 75˚F / 55% humidity.

WARNING

Warranty is void if ventilation is insufficient.

CABINET DRAIN

A.

TRUE Freezer Merchandiser Cabinets have a drain at

the bottom of the unit. (See image 1). When cleaning

the unit make sure the drain hose is connected to a

hose that is routed to a floor drain.

Cabinet
Drain

Exterior Cabinet
Drain

INSTALLATION / OPERATION INSTRUCTIONS

2