background image

............ www.truemfg.com ............

True Food Service Equipment, Inc.

4

4

INSTALLATION / OPERATION INSTRUCTIONS

To ensure that your unit works properly from the first

day, it must be installed properly. We highly recommend

a trained mechanic and electrician install your TRUE

equipment. The cost of a professional installation is

money well spent.

Before you start to install your TRUE unit, carefully

inspect it for freight damage. If damage is discovered,

immediately file a claim with the delivery freight carrier.
TRUE is not responsible for damage incurred during

shipment.

OWNERSHIP

• Adjustable Wrench

• Phillips Head Screwdriver

• Level

REQUIRED TOOLS

The following procedure is recommended for uncrating

the unit:
A. Remove the outer packaging, (cardboard and bubbles

or styrofoam corners and clear plastic). Inspect for

concealed damage. Again, immediately file a claim

with the freight carrier if there is damage.

B. Move your unit as close to the final location as

possible before removing the wooden skid.

NOTE

Keys for freezer with door locks are located in warranty packets.

C. Insert key with lock into the key hole. Turn and pull

the key out. The lock will stay in the key hole.

D. To remove the lock from the key hole simply do the

reverse process. Insert the key into the lock. Turn and

pull the key and lock out of the key hole.

(See images 1-3)

UNCRATING

INSTALLATION / OPERATION INSTRUCTIONS

• Remote cabinets must be ordered as remote. We do

not recommend converting a standard self contained

to remote system.

• All remote cabinets must be hard wired.
• Remote cabinets are not available with castors.
• All remote cabinets come standard using 404A

refrigerant.

• All remote units come standard with expansion valve,

liquid line solenoid, heated condensate pan, and

defrost timer when applicable.

• Contact TRUE Technical Service for BTU

requirements.

• No wiring necessary between cabinet and condensing

unit.

• All remote condensing units purchased from TRUE

are 208/230 volts single phase.

If you have any questions regarding this section, please

call TRUE at 1 (800) 325-6152.