Install blower in hood, Figure 15: weld stud locations, Figure 16: attachment of additional screws – Thermador PROFESSIONAL PH PH54 User Manual
Page 12: Caution

English 10
Install Blower in Hood
1. The blower is attached to the hood using weld studs
provided on the mounting plate.
2. Figure 15 shows the weld studs in location B for
horizontal (rear) discharge. Attach four (4) #10-24 nuts
to the weld studs. For vertical discharge, attach nuts to
studs at the top of the mounting plate.
3. Guide the motor mounting plate over the studs and
tighten nuts to secure the blower to the hood.
4. Attach two (2) additional screws as shown in Figure 16.
CAUTION:
Verify that the two (2) additional screws in
Figure 16 are installed and properly tightened
before continuing.
Figure 15: Weld Stud Locations
Figure 16: Attachment of Additional Screws