3. Rigging-Strength Ratings, Safety

Factors, and Special Safety Considerations

3.1 Working-Load Limit and Safety Factor Definitions:

The structural ratings for all of the X-Line rigging components and complete loudspeaker systems

are based on test results in which parts were stressed to failure. Manufacturers typically present

the structural-strength ratings of mechanical components or systems as either the working-load

limit (WLL) or the ultimate-break strength. Electro-Voice chooses to present the structural-load

ratings of the X-Line loudspeaker systems as the working-load limit. The working-load-limit rating

represents the maximum load that should ever be applied to a mechanical component or system.

THE USER SHOULD NEVER APPLY A LOAD THAT EXCEEDS THE WORKING-

LOAD LIMITS OF ANY OF THE RIGGING COMPONENTS OR COMPLETE

LOUDSPEAKER SYSTEMS DESCRIBED IN THIS MANUAL.

The working-load limits for the X-Line rigging components and complete

loudspeaker systems described in this manual are based on a 5:1 safety factor. The safety factor

is defined as the ratio of the ultimate-break strength divided by the working-load limit, where the

ultimate-break strength represents the force at which a part will structurally fail. For example, if a

part has working-load limit of 1,000 lb (454 kg), it would not structurally fail until a force of at least

5,000 lb (2,268 kg) was applied, based on a 5:1 safety factor. However, the user should never

apply a load to that part that exceeds 1,000 lb (454 kg). The safety factor provides a margin of

safety above the working-load limit to accommodate normal dynamic loading and normal wear.

CAUTIONS for Working-Load Limits and Safety Factors:

The working-load limits defined by the manufacturer of any rigging component should never be

exceeded. Electro-Voice bases the working-load limits of its X-Line products on a 5:1 safety

factor. A 5:1 safety factor is fairly common amongst rigging manufacturers because many

regulatory agencies call for a minimum safety factor of 5:1.

The user is cautioned that some local regulations may require safety factors higher than 5:1. In

that circumstance, Electro-Voice insists that the user maintain the higher safety factor as required

by the local regulations throughout the entire X-Line installation. It is the responsibility of the user

to make sure that any X-Line installation meets any applicable local, state or federal safety

regulations.

3.2 Structural Rating Overview

There are two independent strength ratings that, together, give a complete description of the

overall structural performance capabilities of any X-Line loudspeaker system. They are defined as

follows:

1. The strength of each individual rigging point; which is the combined strength of the rigging

track mounted on the enclosure with the removable rigging-hinge and/or rigging-strap assemblies.

2. The total strength of the overall enclosure; which is a function of the combined forces from

all of the rigging points acting on the enclosure as a whole.