beautypg.com

Troubleshooting 14. specifi cations – Tripp Lite NetDirector B060-032-8 User Manual

Page 48

background image

48

Troubleshooting for Sun Systems

Problem Solution
Video display problems with HDB-15

The display resolution should be set to 1024x768@60Hz. Under text mode:

interface systems

1. Enter the OK prompt (see page xx) and issue the following fi rmware commands.

(e.g. Sun Blade 1000 Servers).

setenv output-device screen:r1024x768x60 reset-all

Under

XWindow:

1. Open a console and issue the following command:

M64confi g –res 1024x768x60

2.

Log

out.

3.

Log

in.

Video display problems with 13W3 interface The display resolution should be set to 1024x768@60Hz. Under text mode:
systems (e.g. Sun Ultra Servers).*

1. Enter the OK prompt (see page xx) and issue the following fi rmware command.

setenv output-device screen:r1024x768x60 reset-all

Under

XWindow:

1. Open a console and issue the following command.

ffbconfi g –res 1024x768x60

2. Log out.

3. Log in.

*These solutions work for most common Sun VGA cards. If these procedures fail to resolve the problem, consult the manual for the Sun VGA card.

Product Specifi cations

Computer Connections – Direct

32

Computer Connections – Maximum

8,000+

Console Connections

8

Port Selection

OSD & Hotkeys

Console Port Connectors

(8) RJ45 Female

Computer/Server Connectors

(32) RJ45 Female

Daisy-Chain Connectors

(1) HPDB-15 Female

LAN Connectors

(1) RJ45 Female

Power Connectors

(1) IEC-320-C13

Reset Switch

Yes

Power On/Off Switch

Yes

Firmware Upgrade Recovery Switch

Yes

Extra User Port 1

Yes, on Front Panel

User Port LEDs

8 (Green)

Server Port LEDs – Online/Selected

32 dual-colored

(Green/Red/Amber)

Power LED

1 (Blue)

I/P Rating

100-240V, 50/60Hz, 1A

Power Consumption

120V/19W, 230V/20W

Keyboard/Mouse Emulation

PS/2, USB (PC, Mac, Sun), Serial

Auto Scan Interval

1-240 Seconds (User-Defi ned)

Video 1024x768@60Hz

(300m Max.), DDC2B

Operating Temperature

0-50° C, 32-122° F

Storage Temperature

-20-60° C, -4-140° F

Humidity

0-80% RH, Non-Condensing

Housing Type

Metal

Weight 13.6

lbs

Dimensions (H x W x D)

1.8” x 17” x 10”

13. Troubleshooting

14. Specifi cations

Entering the ok Prompt (Sun Solaris)

If you are using a PC keyboard to control a Sun Solaris server and want to use Stop-A keys to enter the OK prompt, do the following:

Press and release CTRL, press and hold down [T], and then press [A].

Note: Before entering the OK prompt, consult the server’s documentation for any precautionary steps that you should take.