Configuration commands

Description

xConfiguration Zones Zone [1..100]
Gatekeeper IP Port: <1..65534>

Specifies the IP port of the neighbor gatekeeper

xConfiguration Zones Zone [1..100]
Gatekeeper HopCount: <1..255>

Maximum hop count to use when issuing LRQs to Gatekeepers
in this zone.

The default is 15 hops.

xConfiguration Zones Zone [1..100]
Name:

Specifies the name of a zone in the zone list

xConfiguration Zones Zone [1..100]
Prefix Match:

Prefix to use for the indexed zone.

xConfiguration Zones Zone [1..100]
Prefix Mode:

Whether or not to strip prefixes when forwarding an LRQ to the
indexed zone.

The default is Include.

5.3 Command

The command root command, xcommand, is used to execute commands on the Gatekeeper.

To list all xcommands type

xcommand ?

To get usage information for a specific command, type

xcommand ?

Command

Usage

Description

AllowListAdd

xCommand AllowListAdd

Adds an entry to the allow list, used by the registration
restriction policy.

AllowListDelete

xCommand AllowListDelete

Removes the pattern from the allow list at the specified
index.

Boot

xCommand Boot

Restarts (boots) the Gatekeeper.

This takes approximately 1 minute to complete.

CheckBandwidth

xCommand CheckBandwidth

Diagnostic function for verifying bandwidth control. Node1,
Node2 are the case sensitive names of the nodes,
bandwidth the required bandwidth and calltype one of
Traversal or NonTraversal.

CredentialAdd

xCommand CredentialAdd:

Adds the given username and password to the local
authentication database.

CredentialDelete

xCommand CredentialDelete:

Deletes the indexed credential.

DefaultLinksAdd

xCommand DefaultLinksAdd

Restores the factory default links for bandwidth control.

DefaultValuesSet

xCommand DefaultValuesSet
Level:

Resets system parameters to default values.

Level 1 will reset most parameters, except networking
related ones. Level 2 and 3 reset progressively more
parameters.