5.10. Input Sensitivity Setting

Performs input sensitivity setting of Input channel. 9000Series Amplifier responds with the

same data as that received. Input sensitivity setting is enabled only for the channel on

which the D-001T or AN-001T is used.

Note: Command cannot be received during power off.

ACH, 02H, ,

00H - 07H (Input channel 1 - 8)

INPUT SENSITIVITY TABLE

Value

Value

HEX DEC

Sense

(dB)

HEX DEC

Sense

(dB)

00H 0

-10 05H 5

-42

01H 1

-18 06H 6

-48

02H 2

-24 07H 7

-54

03H 3

-30 08H 8

-60

04H 4

-36

Example: Setting the input sensitivity of Input Channel 5 to –24 dB.

ACH, 02H, 04H, 02H

5.11. Phantom Power ON/OFF Setting

Sets the phantom power of Input channel to ON or OFF. 9000Series Amplifier responds

with the same data as that received.

Note: Command cannot be received during power off.

87H, 02H, ,

00H - 07H (Input channel 1 - 8)

00H: PHANTOM OFF

01H: PHANTOM ON

Example: Setting the phantom power of Input Channel 1 to ON.

87H, 02H, 00H, 01H