Page 18 of 24, Frequency value – TOA Electronics 9000 Series User Manual
Page 18

Page 18 of 24
5.9. Filter Settings
Perform Filter (HPF/LPF) settings of Input / Output channels. 9000Series Amplifier
responds with the same data as the receipt.
Note: Command cannot be received during power off.
A2H, 04H,
00H: Input channel
01H: Output channel
00H - 07H (Input channel 1 - 8)
00H - 07H (Output channel 1 - 8)
00H: High Pass Filter
01H: Low Pass Filter
HIGH PASS FILTER
TABLE – 00H
LOW PASS FILTER
TABLE – 01H
Example: Setting the Input Channel 3’s High Pass Filter to 31.5 Hz.
A2H, 04H, 00H, 02H, 00H, 03H
Value
HEX DEC
HPF (Hz)
00H 0 OFF
01H 1
20
02H 2
25
03H 3 31.5
04H 4
40
05H 5
50
06H 6
63
07H 7
80
08H 8 100
09H 9 125
0AH 10 160
0BH 11 200
0CH 12
250
0DH 13
315
0EH 14 400
Value
HEX DEC
LPF (Hz)
00H
0 4k
01H
1 5k
02H
2 6.3k
03H
3 8k
04H
4 10k
05H
5 12.5k
06H
6 16k
07H
7 20k
08H
8 OFF