beautypg.com

Topcon GTS-823A User Manual

Page 37

background image

3-2

3 AUTOMATIC TRACKING / AUTOMATIC COLLIMATION

4

Choose measuring modes by pressing the
soft keys.
Measuring starts.
Sample: Horizontal distance measuring

[F2]

l

If the target prism is lost during auto tracking status, the instrument will automatically change to Waiting
status and symbol mark will be switched. If the target is found during Waiting status, tracking resumes,
and if not, status changes to Searching status. When the target prism is found, tracking will resume.

l

The following symbol marks are indicated at the right side of the display.
In all these status, laser beam is emitting.

l

Auto tracking status sometimes can be unstable for a few seconds after the optical path is disturbed.

l

If the center of reticle and the center of the prism is not coincided, you should adjust optical axis for
auto-tracking, refer to chapter 9"Check and adjustment".

l

In the not suitable operating condition in such the atmospheric condition is not good by the heat
shimmer, or other bad weather condition, in the long distance of the auto-tracking limit, can be
happened not certain tracking or not tracking at the center of the prism.

V : 90°10'20"

HR: 120°30'40" PSM 0.0

HD: < PPM 0.0

VD: (m) *c.R

MEAS MODE VH SD NEZ P1

Star key
mode

Tracking
status

Waiting status

The target prism is lost

The target prism is not found
for some time

Searching status

Automatic tracking

Normal
mode

F1

The target prism
is found

Tracking status

Waiting status

Searching status

This manual is related to the following products: