beautypg.com

Topcon GTS-823A User Manual

Page 118

background image

11-2

11 SETTING ATMOSPHERIC CORRECTION

l

How to Set the Atmospheric Correction Value Directly

Measure the temperature and air pressure to find atmospheric correction value (ppm) from the chart or
correction formula.

[Example] Atmospheric correction value

The display returns STAR key menu.

*1) Range : Temp. -30.0

°

C to +60.0

°

C (0.1

°

C step)

Pres. 560.0 to1066.0hPa (0.1hPa step) , 420.0 to 800.0mmHg (0.1mmHg step)
16.5 to 31.5inHg (0.1inHg step)

*2) When the atmospheric correction value, which is calculated from the input temperature and pressure

values, exceeds the range ± 999.9ppm, the operating procedure returns to step

3

automatically. Input

values again.

Operating procedure

Operation

Display

1

Press STAR (

H

) key.

Press the [F6] key twice to get the page three.

[

H

]

[F6] twice

2

Press the [F2] key.
Current setting value is displayed.

[F2]

3

Move the cursor (>) to ppm setting by
pressing [F5](

) key.

Move

cursor

4

Enter atmospheric correction value and press
[ENT] key. *1)

Enter ppm

[ENT]

The display returns previous mode.

*1) Input range : -999.9mm ~ +999.9mm, 0.1mm step

2003-10-10 14:30:40

3

20.0

°

C

5.1ppm

-2.0 mm

1012.0hPa

5.1ppm

-2.0 mm

This manual is related to the following products: