2 mounting the remote humidity sensor – Therma-Stor Products Group HI-E Dry Vehere User Manual
Page 4
4
www.thermastor.com • [email protected]
Toll-Free 1-800-533-7533
3.1D In Remote Area, Duct Inlet & Outlet
It is often desirable, to install the Vehere in an adjacent
equipment room or unfinished area. Air is then transferred
between the humid room and the unit via ducting. Remotely
mount the Vehere humidity control in the humid room and
wire to the Vehere. Local electrical codes must be followed
when wiring the control. Refer to the “Mounting the Humidity
Sensor/Controller” section which follows. (See Fig. 5)
3.2 Mounting The Remote Humidity Sensor/
3.1C In Humid Area, Duct Inlet and/or Outlet
If the pool room is very large or has high ceilings,
dehumidification can be improved by adding an inlet and/
or outlet duct to circulate and destratify stagnant areas.
Add inlet or outlet ducting to create flow across the area’s
greatest length. For areas with ceilings higher than 12’, use
an inlet duct to draw warm, moist air from near the ceiling.
See section 4.5 for attaching duct collars & ducting. (See
Fig. 4)
Dehumidistats
for
Quiet-Vent
and
remote
Vehere
Direct Warm & Dry Air
Toward Window Glass
Quiet-V
ent
Optional
Quiet-Vent
Exhaust Ventilator
Low = 165 CFM
high = 290 CFM
Vehere
Pool & Spa
Humidity Controller
Figure 4: Installation in humid area with ducting.
Quiet-V
ent
Dehumidistats
for
Quiet-Vent
and
remote
Vehere
Direct Warm & Dry Air
Toward Window Glass
Optional
Quiet-Vent
Exhaust Ventilator
Low = 165 CFM
high = 290 CFM
Vehere
Pool & Spa
Humidity Controller
Figure 5: Installation in remote area with ducting.