1 Intended Application

The intended application for the Vehere is as a pool &

spa area humidity sensing controller applied either as a

free-standing device directly in the pool area or operated

remotely to provide dehumidified air to the pool or spa area

using optional ducting and remotely mounting the humidity

controller. The Vehere high efficiency dehumidifier utilizes

refrigeration to cool an incoming air stream below its

dewpoint as it passes through an evaporator coil. This

cooling results in the removal of moisture (latent heat). The

cooled and dried air is used to pre-cool the incoming air

stream resulting in up to a 200 percent increase in overall

efficiency.

2 Specifications

Model:

HI-E Dry Vehere

Electrical:

110-120 VAC, 12.0 Amps, grounded

(7’ power cord included)

Compressor LRA:

63 Amps

Capacity:

192 pints/day @ 80°F, 60% RH

Energy Factor:

2.79 L/kWh

Air Flow:

540 CFM without external ducting

510 CFM @ .15 IWG external static

Refrigerant Charge:

2 lbs., 8 oz. R410a

Optional Duct Connections:

12” round inlet & outlet

Size (w/o duct collars):

36.5” Long x 19” Wide x 40” High

Weight:

180 lbs.

Controller Accuracy:

+/- 5% RH @ 72°F

Capacities
The Vehere is designed to control humidity for indoor pool

(spa, hot tub) areas. It consists of a controller, dehumidifying

cooling system, filter, fan and delivers the following

dehumidification capacities:
Air Temp/Relative Humidity

Lbs./Hour

Lbs./Day

82°F/60%RH*

8.67

208

80°F/60%RH

8.32

200


Air Temp/Relative Humidity

Pints/Hour

Pints/Day

82°F/60%RH*

8.33

200

80°F/60%RH

8.00

192

Air Temp/Relative Humidity

BTUs/Hour

KWH/Day

(derived)

82°F/60%RH*

13,668

35.71

80°F/60%RH

13,299

34.56

*ASHRAE Recommended Conditions

Read these installation, operation and service instructions

carefully before installing and using this unit. Proper

adherence to these instructions is essential to obtain

maximum benefit from your Vehere pool & spa humidity

controller.

• If used near a pool or spa, be certain there is NO chance

the unit could roll into the water or be splashed and that

it is plugged into a GROUND FAULT INTERRUPTER.

• DO NOT use the Vehere as a bench or table.
• Avoid discharging the exhaust directly at people or pets.

Table of Contents
Precautions..............................................................................1
1. Intended Application for Vehere

....................................1

2. Specifications & Capacities

............................................1

2.1 Vehere Diagram .........................................................2

3. Installation

.......................................................................2

3.1 Location .....................................................................2

3.1A Improper Installation .........................................2

3.1B In humid area, no ducting ................................3

3.1C In humid area, duct inlet and/or outlet ...........4

3.1D In remote area, duct inlet & outlet ..................4

3.2 Mounting the Humidity Sensor/Controller ..............5

3.3 Electrical Requirements ............................................5

3.4 Condensate Removal ................................................5

3.5 Ducting .......................................................................5

3.5A Ducting kit .........................................................5

3.5B Ducting for Dehumidification ...........................6

4. Operation

.........................................................................6

4.1 Humidity Control ........................................................6

4.2 Humidity Control Adjustment ....................................6

4.3 Fan Switch .................................................................6

4.4 Automatic Defrost Control ........................................6

4.5 Automatic Low Pressure Control ..............................6

5. Ventilation

........................................................................7

5.1 Ventilation Recommendations .................................7

6. Maintenance

....................................................................7

6.1 Air Filter ......................................................................7

7. Service

..............................................................................7

7.1 Technical Description ................................................7

7.2 Troubleshooting .........................................................7

7.3 Refrigerant Charging .................................................8

7.4 Blower Replacement .................................................8

7.5 Relay ...........................................................................8

8. Vehere Accessories