3

www.thermastor.com • [email protected]

Toll-Free 1-800-533-7533

2.1 Vehere Diagram

A - Air Intake
B - Humidity Sensor/Control
C - Filters
D - Air Exhaust
E - Fan Switch
F - Power Cord
G - Drain Hose

Figure 1: Vehere diagram.

36.5”

A

C

C

B

E

D

G

F

40”

19”

Vehere

Pool & Spa

Humidity Controller

Figure 2: Installation clearance requirements

Figure 3: Installation in humid area with no ducting

3 Installation Options

3.1 Location

The Vehere can be installed in a variety of locations to meet

the owner’s needs; other considerations include:
1. Providing access to a 115 VAC power outlet (7’ power cord

is provided).

2. Locating near a floor or other suitable drain (4’ drain hose

included).

3.1A Improper Installation
Do not install the Vehere with the exhaust of the unit within 3’

of a wall or obstruction. Do not place the unit near open water.

(See Fig. 2)

3.1B In Humid Area, No Ducting
The simplest installation is to place the Vehere in the pool area

with no ducting. The Vehere must be at least 3’ from walls and

other air obstructions, at the return and supply sides of the

Vehere. (See Figure 3)