Removing the remaining packing materials, Figure 18 – Quantum Audio Tape Library PX502 User Manual
Page 12

PX502 Tape Library Quick Start Guide
12
Figure 18 Turning on the Library
The power up sequence can take several minutes. The 
first message displaying will be “Are the internal 
packaging materials removed?” Continue with 
Removing the Remaining Packing Materials
Removing the Remaining Packing Materials
0
Now that you have installed the library chassis and powered 
on the system, you MUST remove the remaining packing 
materials from the library chassis before the library is 
operational.
1 Put on an antistatic wrist strap and clip it to the library
chassis.
2 IF there is space above the library to remove the top
cover, remove the twelve PHILLIPS screws securing the 
top cover and FlexLink cover to gain further access to 
the internal packaging restraints (see 
is no space above the PX502 library to remove the top 
cover, continue with Step 3.
C
AUTION
: Take standard ESD precautions when
performing this procedure.
Power button
OCP
Figure 19 Removing the Top 
Cover (Optional Step)
3 When the library powers on for the first time, the OCP
asks you: “Are the packaging materials removed?” (YES 
or NO).
4 Press NO to continue. The OCP displays “Doors opened,
magazines released, pull magazines out before power 
shutoff.” The library waits approximately 30 seconds 
for you to open the doors, remove both magazines 
from the library, and remove the foam blocks.
C
AUTION
: Pressing Yes when the internal packaging
restraints are in place will damage the library 
robotics. 
N
OTE
: If you are unable to remove the magazines before
the library shuts down. Turn on the library power 
and repeat the steps above.