Cb 1200 pellet stove, E. vertical - internal - typical installation – Quadra-Fire CB1200M-MBK User Manual
Page 15
R
December 16, 2011
7014-179D
Page 15
CB 1200 Pellet Stove
We recommend a minimum of 60 in. (1.5m) vertical,
however above the eave is preferred.
Both installations are approved for mobile home instal-
lations. Must use 3 or 4 inch (76 to 102mm) “L” or
“PL” Listed pellet venting or listed double wall pipe and
Quadra-Fire outside air kit in mobile homes. Single
wall pipe is approved for residential installations only.
C. Vertical into Existing Class A Chimney
D. Through The Wall & Vertical - External
Firestop
Flashing
Rain Cap
6 in.
(152mm)
Min.
Non-combustible Hearth Pad
3 in. (76mm)
Min.
Clean-out
Cover
24 in. (610mm)
minimum
Ceiling Support
Class A Chimney
Connector Adapter
Top Vent Kit
Non-combustible Hearth Pad
Clean-out Cover
Tee
Wall Thimble
Support Bracket
every 60 in. (1524mm)
24 in. (610mm)
Minimum
Rain Cap
Flashing
2 in. (51mm) Minimum
6 in. (152mm)
Minimum
Figure 15.1
Figure 15.2
E. Vertical - Internal - Typical Installation
Firestop
Flashing
Rain Cap
6 in.
(152mm)
Min.
Non-combustible Hearth Pad
3 in. (76mm)
Min.
24 in.
(610mm)
Minimum
3 in. to 3 in.
(76-76mm)
Top Vent Kit
Clean-out Cover
Figure 15.3