Quatech QSP-200/300 User Manual
Page 38
Example 2
DEVICE=C:\QSP-200\QSP200.SYS (7,120,15) (3,300,4)
In example 2, the Client Driver will attempt to configure the QSP-200/300 as COM3 through
COM6 using I/O address 300-31F hex and IRQ 4. If COM3, 4, 5, or 6 already exists, or if the
I/O address or IRQ resources are already in use, the Client Driver will attempt to configure the
QSP-200/300 as COM7 through COM10 using I/O address 120-13F hex and IRQ 15. If COM7,
8, 9, or 10 already exists or if the I/O address or IRQ resources are already in use, the
QSP-200/300 will not be configured. Up to two QSP-200/300s can be installed in this system.
5.1.3 Advanced Configuration Topics
For some applications, it may be desirable to specify the resources for one QSP-200/300 while
allowing the OS/2 Plug-and-Play system to assign the hardware resources for any additional
cards. This can be accomplished by mixing the configuration methods on the QSP-200/300
Client Driver command line
DEVICE=C:\QSP-200\QSP200.SYS (3,100,5) COM7
It is important to remember that when a QSP-200/300 is inserted into a PCMCIA socket, the
client driver will configure the card as a series of COM ports, starting with the lowest available
port number in the list.
Another common application requirement is to have a QSP-200/300 inserted into socket 1 be
configured as COM3 through COM6 while a QSP-200/300 inserted into socket 2 be configured
as COM7 through COM10. This type of configuration is supported by appending a "=Sx"
parameter after any command line argument.
DEVICE=C:\QSP-200\QSP200.SYS COM3=S1 COM7=S2
DEVICE=C:\QSP-200\QSP200.SYS (3,100,4)=S1 (7,300,3)=S2
QSP-200/300 User's Manual
32