Oracle Audio Technologies Sun StorageTek ATCA 4Gb FC Dual Port HBA SG-XPCIE2FC-ATCA-Z User Manual
Page 18
12
Sun StorageTek ATCA 4Gb FC Dual Port HBA Installation Guide • April 2010
3. Observe the port LEDs status for the power-on self test (POST) results as
shown in
summarizes port LED indicator combinations. Refer to
FIGURE 2-4
to
determine the location of the LEDs. Each port has a corresponding set of LEDs
that provide a visual indication of the operating state.
TABLE 2-2
Port LED Indicator Status Definitions
Green LED
Yellow LED
State
On
1 fast blink
1-Gb link rate - Normal operating state, link up
On
2 fast blinks
2-Gb link rate - Normal operating state, link up
On
3 fast blinks
4-Gb link rate - Normal operating state, link up
Off
Off
One of the following:
• Wake-up failure (failed board)
• Server not powered on
• Server not providing power to the board
Off
On
POST failure (failed board)
Off
Slow blink
Wake-up failure monitor
Off
Fast blink
Failure in POST
Off
Flashing
POST processing in progress
On
Off
Failure while functioning
On
On
Failure while functioning
Slow blink
Off
Normal - link down
Slow blink
On
Not defined
Slow blink
Slow blink
Off-line for download
Slow blink
Fast blink
Restricted off-line mode (waiting for restart)
Slow blink
Flashing
Restricted off-line mode, test active