Installer manual 26 – Orbit Manufacturing Rokonet ORBIT-6 RP-206 User Manual
Page 26

Installer Manual
26
Comments on System Controls (Location 30: 2
nd
Digit)
Silent Panic
Bell Squawk on Arming
3 Minute Bypass Enabled
If “NO”, the panic alarm
will be AUDIBLE at the
External Sounder and
visual on the keypad.
If “YES”, the panic alarm
will be INAUDIBLE at
the External Sounder
and invisable on the
keypad.
If selected,
Bell Squawk on
Arming will produce a brief
confirmation “chirp” from the
system’s external sounder(s)
once the system is armed
and the Exit Delay expires
If selected,
3-Minute Bypass Enabled
bypasses all zones automatically for 3
minutes when power is restored to an
“unpowered” system–to prevent
potential false alarms by allowing time
for the stabilization of motion and/or
smoke detectors
Location: 30
System Controls: (1
st
Digit):
1
st
Digit
Loudspeaker/Bell-Siren
UO Extender
Quick Bypass
Quick Arm
0
Bell-Siren
No
No
No
1
Bell-Siren
No
No
Yes
2
Bell-Siren
No
Yes
No
3
Bell-Siren
No
Yes
Yes
4
Bell-Siren
Yes
No
No
5
Bell-Siren
Yes
No
Yes
6
Bell-Siren
Yes
Yes
No
7
Bell-Siren
Yes
Yes
Yes
8
Loudspeaker
No
No
No
9
(default)
Loudspeaker
No
No
Yes
A
Loudspeaker
No
Yes
No
B
Loudspeaker
No
Yes
Yes
C
Loudspeaker
Yes
No
No
D
Loudspeaker
Yes
No
Yes
E
Loudspeaker
Yes
Yes
No
F
Loudspeaker
Yes
Yes
Yes
Location: 30
System Controls: (2
nd
Digit):
2
nd
Digit
3 Minute Bypass
CZ Installation
Bell Squawk on
Arm
Silent Panic
0
Disabled
No
No
No
1
Disabled
No
No
Yes
2
Disabled
No
Yes
No
3
Disabled
No
Yes
Yes
**4
Disabled
Yes
No
No
**5
Disabled
Yes
No
Yes
**6
Disabled
Yes
Yes
No
**7
Disabled
Yes
Yes
Yes
8
Enabled
No
No
No
9
Enabled
No
No
Yes
A
Enabled
No
Yes
No
B
(default)
Enabled
No
Yes
Yes
**C
Enabled
Yes
No
No
**D
Enabled
Yes
No
Yes
**E
Enabled
Yes
Yes
No
**F
Enabled
Yes
Yes
Yes
** New in Ver. 1.3