Viewing the Contents of a Location
It’s often necessary to check the data stored in a memory
location to be sure it’s correct. If improper data is found, it must
be corrected in order to obtain the desired system response. The
data in a location can either be a number (from 0-9) or a letter
(from A-F). Doing so takes advantage of the hexadecimal
numbering system. For our purposes, the characters A through F
will be referred to as hexadecimal digits.
Whenever the Installer Programming mode is active, the first 4
keypad’s Zone LEDs (1-4) are used to reveal each digit in a
selected location. By adding up the values assigned to the lit
LEDs, the contents of any location can be determined. See table
below.
ZONE LEDs
ZONE LEDs
I.D.:
4
3
2
1
I.D.:
4
3
2
1
Value: 8
4
2
1
value: 8
4
2
1
0
off
off
off
off
8
ON
off
off
off
1
off
off
off
ON
9
ON
off
off
ON
2
off
off
ON
off
A
ON
off
ON
off
3
off
off
ON
ON
B
ON
off
ON
ON
4
off
ON
off
off
C
ON
ON
off
off
5
off
ON
off
ON
D
ON
ON
off
ON
6
off
ON
ON
off
E
ON
ON
ON
off
7
off
ON
ON
ON
F
ON
ON
ON
ON
EXAMPLE: Zone 4-ON Zone 3-off Zone 2-off Zone 1-ON TOTAL = 9
EXAMPLE: Zone 4-ON Zone 3-off Zone 2-ON Zone 1-ON TOTAL = B
Hexadecimal Digits
In some locations you may be
required to enter hexadecimal
digits A - F to do so see the next
table.
“A” is entered by pressing
[STAY] + [1]
“B” is entered by pressing
[STAY] + [2]
“C” is entered by pressing
[STAY] + [3]
“D” is entered by pressing
[STAY] + [4]
“E” is entered by pressing
[STAY] + [5]
“F” is entered by pressing
[STAY] + [6]