CS Protocols:
When selecting a contact ID & SIA format, all the reporting codes will be automatically
applied to the locations of the reporting codes.
To change a code, enter a new code (according to the type of event – see page 30) to the
corresponding location.
When selecting the Pulsed Protocol the default for all the reported codes will be “00” and
any other code should be entered manually
To remove a particular reporting code from any of the 3 Protocols enter “00” into the
corresponding location.
Important: Choose the code format only after defining the zone parameters. Changing a
zone type after selecting the code format
WILL NOT change the zone’s reporting code and
a faulty report will be sent to the central station.
Digit
Format Name
Interdigit Time
Data Frequency
00
Pulsed Protocol
01
Contact ID
NA
NA
02
SIA
390 ms
1800 Hz
**03
(Ver. 1.3)
Ademco 4/2 Express
Upload/Download Rings: Location 29
Location 29 sets the number of rings that the ORBIT-6 will wait before automatically
answering an incoming call. If such a call was initiated by the alarm company’s
Upload/Download software, a process begins which allows a Remote Programming
session to take place.
Location: 29
Number of Rings
Default: 12
Choose a number of rings greater than that which the customer will normally wait to answer
an incoming call enter two digits; (between 00-15 rings)
Note: if an Answering Machine is in use and so programmed
(see Location 26 / 2
nd
Digit), entries made in this location will be ignored
SYSTEM CONTROLS: LOCATION 30
Location 30 allows you to specify some additional parameters, which determine how the
ORBIT-6 will operate. The location contains two digits.
•
First digit: determine the number (or letter) corresponding to the choices involving
Quick Arm / Quick Bypass / UO Extender / Loudspeaker / Bell-Siren
•
Second digit: determine the number (or letter) corresponding to the use of
Silent Panic / Bell Squawk on Arming / 3 Minute Bypass
Comments on System Controls (Location 30: 1
st
Digit)
Quick Arm
Quick Bypass
UO Extender
Loudspeaker/Bell-Siren
Quick Arm
eliminates the
need for entering
a User Code when
arming to the STAY
or AWAY modes.
simply pressing
[STAY] or [ARM] will
arm the system to
the respective mode
Eliminates the
need to enter a
User Code when
bypassing a zone.
select
UO Extender
if the Utility Output
Expansion Module is
installed
select
Loudspeaker if the
external sounder(s) is NOT
equipped with a built-in sound
driver; doing so causes the
ORBIT-6 to produce an
oscillating frequency for the
device, select
Bell/Siren if the
external sounder(s) is a bell or
a buzzer or equipped with a
built-in electronic sound driver;.
Number
of Rings