10

11

FEATURES AND FUNCTIONS

FEATURES AND FUNCTIONS

Main unit

1. Display: Displays blood pressure and, pulse rate readings, and oscillation pulse level.
2. HIDE Button: Switches display and non-display of measured results.
3. DC jack: Connects the AC adapter.
4. P-SET (pressure setting) Knob: In the AUTO position, inflation level is automatically set.

Otherwise, inflation level can optionally be set manually between 100 and 280 mmHg.

5. MODE Selector: Selects the operation mode.

• One-time Measurement Mode (SINGLE Mode): Measurement with automatic inflation.
• Average Mode (AVG Mode): Automatically measures two (or three) times consecutively.
• Auscultation Mode (MANU Mode): Automatic inflation, automatic deflation, and pressure display for auscultation (does

not measure blood pressure).

• Check Mode (CHECK Mode): Checks the accuracy of pressure display. Displays only pressure.

6. ON/OFF (power) Button: Turns on or off the unit.
7. START Button: Starts the measurement.
8. DEFLATION (deflation control) /Measurement Result Display Switch Button:

• In the MANU Mode, deflates the cuff by approximately 5 to 10 mmHg with each push during deflation.
• In the AVG Mode, switches the display of average values and the measurement results with each push.

9. Air Connector: Connects the air tube.

10. STOP Button: Stops the measurement and deflates air rapidly.

HIDE

P-SET

100

AUTO

140

180

220

260

280

MODE

AVG.

MANU.

CHECK

SINGLE

ON/OFF

A

VG

./1s

t /2nd/3rd

D

EF

L ATIO

N

START

STOP

mmHg

SYS

mmHg

DIA

BPM

PULSE

AC

DC8V

XL

1. Display

2. HIDE (non-display) Button

3. DC jack

4. P-SET (pressure

setting) Knob

5. MODE Selector

6. ON/OFF (power)

Button

7. START Button

8. DEFLATION

(deflation control)
/Measurement
Result Display
Switch Button

9. Air Connector

10. STOP Button

Names of the Parts

(See Page 11 for detail)

Display

HIDE

BPM

mmHg

PULSE

SYS

mmHg

DIA

AC

Systolic blood pressure

Diastolic blood pressure

Pulse rate

Contents when the AVG
Mode is selected

AVG. : Mean value
1st

: First reading

2nd : Second reading
3rd

: Third reading

Ready to Measure /
Pulse synchronization

Pulse level /
Number of irregular pulses

Number of irregular pulse waves: The pulse
wave having a difference of more than 25%
from the average interval of pulse waves is
determined irregular. Number of irregular
pulse waves is displayed up to three times.

Battery level

Displays

for the operable level.

Blinks

for a low charged
level

Displays

for the inoperable
level.

Charging

Displays

when the battery

pack is being charged.

External power source

Displays

AC

when the unit is connected

to the external power source via the AC
adapter.

Example of display

No. of irregular pulses

1

2

3

HEM-907 10/23/03 3:13 PM Page 10