Scaling – Omega Engineering DP3600 User Manual

Page 6

background image

5

PROGRAM LIMITS

1. Process Limit1
2. Process Limit2
3. Setup limt 3 for Rate/Process
4. Process Limit 3
5. Setup Limit4 for Process/Deviation
6. Process Limit 4
7. Timer 1 Limit
8. Timer 2 Limit
9. Deadband for limits
9. Limits Normally open/close (1 Thru 4)
10. Limits Latching/Non Latching
11. Audio Alarm On/Off

PROGRAM SYSTEM

1. Display Options
2. Flash Time
3. Engineering units
4. Program Setpoint
5. Remote Tare/Hold
6. Input Type
7. Input Range

SCALING

1. High Scale
2. Low Scale
3. Offset
4. Tare

Programming Group Selection:


On entering correct passcode, setup procedure starts. The very first step will let you select one of the three
groups of parameters that you can program. Three available groups are: 1) SCALING 2) PROGRAM
LIMITS 3) PROGRAM SYSTEM. Each group will let you program various parameters as shown below:

Push ^v key to move from one programming group to the next. When a desired group is displayed, push
SETUP key to select it.

SCALING

Decimal point:


Decimal point mode is indicated as ‘dp 9999’ (dp stands for DECIMAL POINT). Push ^v key to program
decimal point. Each push on the ^v key moves the decimal point to the next position. After 9.999 the display
will go to 9999. When proper decimal point position has been obtained push SETUP key to go to the next
mode.

High Scale:


High scale mode is indicated by a brief display of the message ‘HI SCLE’ followed by high scale value.
The least significant digit (right most digit) will be flashing. The flashing indicates that pushing ^v key will
increment or decrement that particular digit. Pushing ^v key once and holding it down will increment the
flashing digit. Releasing the ^v key and pushing it again immediately ( and then holding it in) will start
decrementing the display. The desired number can be programmed by toggling the ^v key. To move to the
next significant digit push key, and to increment or decrement it, use ^v key. After obtaining a new
high scale value (or to retain the current one) push SETUP key to get to the next mode.

Low Scale:


Low Scale mode is indicated by the display first flashing ‘LO SCLE’ and then the pre-programmed value
of low scale. Again, to change the flashing digit value use ^v key. To change any other digit, use
key to make that digit flash and then use ^v key to change its value. After obtaining a new value (or to retain
the present value) push setup key. This will also get you into the next function.