beautypg.com

Optima 45 - 3 – Optima Company Optima 45 - 3 User Manual

Page 29

background image

Optima 45 - 3

29

If a wall-mounted switch or a wall-mounted thermostat is desired, Archgard recommends that
the device be wired as shown in Fig 1.

Note: Archgard Industries does not manufacture or sell any wall switch or wall thermostat and
will not extend warranty to them.

OPTIONAL WALL SWITCH OR THERMOSTAT

Thermostat / wall switch wire table

Recommended Maximum Lead Length for two wires

Wire Size

Max. Length

14 GA.

50 Ft. (15.24 M)

16 GA.

32 Ft. (9.75 M)

18 GA.

20 Ft. (6.09 M)

20 GA.

12 Ft. (3.65 M)

22 GA.

9 Ft. (2.74 M)

VALVE CONNECTION FOR MILLIVOLT VALVE

Fig. 1

A

ELECTRODE

B

THERMOPILE

C

PILOT CAP

D

THERMOCOUPLE

PILOT ASSEMBLY

B

A

C

D

ON / OFF SWITCH

WIRE TO
PIEZO
(SPARKER)

OPTIONAL

WALL

SWITCH, WALL

THERMOSTAT

OR REMOTE

CONTROL

THERMOCOUPLE LEAD

PILOT SUPPLY TUBE