Advance settings, Decode time & led’s for non standard inks – Opticon LH2 User Manual
Page 86
Advance Settings
86
Advance Settings
87
Advance Settings
Command Name: Decode Time & LED’s for Non Standard Inks
Usage:
Sets the Decode Time and LED to read a bar code.
Description:
The default settings for the LH2 are designed for optimal, general
purpose performance with good quality symbols on typical surfaces.
For poor quality barcodes or barcodes on non-standard surfaces
(shiny, low-contrast), the unit may require:
• More time to process the barcode before the system abandons the
image and restarts on a new decode attempt.
• May require manipulating LED’s.
To allow for additional processing time or to change the LED settings
for marginal symbols, use one of the following commands.
Default:
Normal Decode Time is ON.
LED’s for Non Standard Inks are OFF.
Programming Code:
Serial Command:
Extra Long Decode Time
P%AA0200<┘
Note:
Utilizing this feature may affect the overall performance of the
reader, but “unreadable” barcodes may become readable.
Options:
Programming Code:
Serial Command:
Normal Decode Time (Default)
P%AA100<┘