3 configuration command string – Ovation Software Label Printer User Manual
Page 33
Printing Labels
Ovation
2
25
2.3
Configuration Command String
The configuration command string sets the operating parameters of
the printer. The command strings are described below.
where w:
Bit # Function
Value
0-2
Baud Rate
0=9600*, 1=600, 2=2400, 3=19200, 4=4800, 5=N/A,
6=1200, 7=9600 Test Mode
3
Word Length
0=8 bits*, 1=7bits
4&5
Unused
Set to 0
6
Always 1
Set to 1
7
Always 0
Set to 0
where x:
Bit # Function
Value
0
Print Method
0=direct thermal*, 1=thermal transfer
1
Present Sensor
0=not equipped, 1=equipped
2
Alternate Char.
Set
0=standard*, 1=main frame
3
Cutter
0=disabled*, 1=enabled
4&5
Unused
Set to 0
6
Always 1
Set to 1
7
Always 0
Set to 0
where y:
Bit # Function
Value
0&1
Paper Type
0=gap*(edge), 1=reflective, 2=continuous (3")
2
Unused
Set to 0
3-5
Unused
Set to 0
6
Always 1
Set to 1
7
Always 0
Set to 0
* = factory defaults
Example:
@
Sets the printer to: 9600 baud; 8 bit word length/no parity.
A
Sets the printer to: thermal transfer; no present sensor;
standard character set; no cutter.