beautypg.com

Omega Engineering GP901 User Manual

Page 4

background image

GP901 M-3343 05/08

Network type

Orbit - RS485 2-wire multi-drop (up to 31 per channel)

Network speed

1.5Mbaud, 187.5k Baud or 9600 Baud (do not use 9600

Baud for New Applications as this will be phased out)

Network Control Character

Break Character - low (space) of >90 us (187.5k Baud) or

>1.2mS (9600 Baud)

Command Character Format

1 start, 8 data, 1 odd parity, 1 stop bit

Accuracy
The error quoted assumes periodic re-setting against a setting master in accordance with normal gauging

practice (not less than once per day). As the Digital Probe may be used anywhere on its stroke the setting

master itself must be of known dimensions, but does not need to be precisely on its nominal value. The error

quoted for the Digital Probe therefore includes a factor dependant on the distance between the setting master

and the component being gauged.

Where D = difference in mm between setting master and component.

Error at calibration temperature: -

0.5 mm Probes i.e. GP901-05-S

6

0.05 mm 6 0.2% x D

1 mm Probes i.e. GP901-1-S

6

0.1 mm 6 0.1% x D

2 mm Probes i.e. GP901-2-S, GP901-2-P

6

0.1 mm 6 0.1% x D

5 mm Probes i.e. GP901-5-S, GP901-5-P

6

0.1 mm 6 0.2% x D

10 mm Probes i.e. GP901-10-S, GP901-10-P

6 0.1 mm 6 0.2% x D

20 mm Probes i.e. GP901-20-S, GP901-20-P

6

0.1 mm 6 0.2% x D

Gauge Head Specifications
Specifications Common to All Gauge Head Types
Body Material

Stainless Steel 400 Series

Probe tips

various types available

Non-repeat

<0.15 mm

Max. Angular Rotation of Tip

2

°

Gaiter Material

Viton®

Max. Probe tip tightening Torque

0.22 Nm – M2.5 Thread

(when changing tip please take care not to damage probe) 0.12 Nm – M2 Thread

Storage Temperature Range

-20

°

C to +100

°

C

Operating Temperature

+5

°

C to +80

°

C

Environmental Protection (see mounting notes)

IP 65 (with gaiter)

Cable Standard (not all types)

2m screened, PUR, insulation

Option (not all types)

Standard cable with stainless steel or plastic braid

Pneumatic Operation (Not GP901-05 version)

Minimum operating pressure With Gaiter

(bar) Without Gaiter

0.4

0.3

Maximum operating pressure With Gaiter

(bar) Without Gaiter

1.0

2.0

Air leak rate ml/min. at 1.0 bar With Gaiter

Without Gaiter

<10

<150