GP901 M-3343 05/08

Introduction
The Digital Probe is a gauging transducer combined with conditioning electronics in a permanently

connected ”smart connector” or PIE (Probe Interface Electronics).

The PIE converts and corrects the output from the gauge head and transmits the result in a digital format

using the Orbit protocol. Because the Digital Probe is factory calibrated using a reference Laser, the probe

has a very linear output with position.

The Digital Probe is one of an extensive range of Orbit Modules available for use with the Orbit

Measurement System, which provides an easy way to construct and maintain a complete measurement

system of up to 372 Orbit modules.

The Orbit protocol features an extensive set of commands that enable fast and efficient transmission of

data between the Orbit module and the PC.

Digital Probe Specifications
This section contains the specifications of the Digital Probe. There are two sections, the first are the

specifications for the complete Digital Probe (PIE + gauge head) and the second is mechanical data

relevant to the gauge head only.

PIE is designed to be primarily used with the T-CON connector. Full details of mounting with T-CON refer

to the section of PIE and T-CON installation.

Digital Probe Data

Performance Data
Basic Probe Type

GP901-05 GP901-1 GP901- GP901-5 GP901-10 GP901-0

Calibrated Stroke mm

0.5

1

2

5

10

20

Full Mechanical Travel

0.58

1.5

3 (*2.5)

6

11

21

Resolution (14 bit over stroke) mm

0.03

0.061

0.122

0.305

0.610

1.22

Resolution (16 bit over stroke)

N/A

0.015

0.03

0.076

0.152

0.305

Resolution (18 bit over stroke)

N/A

N/A

N/A

0.019

0.038

0.076

Accuracy mm

see Accuracy section below

Repeatability

<0.1 mm

<0.15 mm

Reading Rate per Network channel

1000 readings / second minimum

Reading Rate (per PIE)

240 readings / second minimum (4 ms internal update)

in Normal Mode

Up to 3906 readings per second in dynamic (8 probes per network)

Calibration Temperature

2061

°

C

Temperature Range

0 to 60

°

C

Warm up Period

30 minutes

General Data
Supply Voltage

5 60.25Vdc

Current Consumption

0.06 A max.

PIE per Orbit channel

31 modules