4 crystal optical fiber cable (agf) – Omron C-series User Manual
Page 19
2-4
Section
Crystal Optical Fiber Cable (AGF)
9
7. Do not allow heavy objects to fall on optical cable or otherwise subject it to
excessive shock or strain.
2-4
Crystal Optical Fiber Cable (AGF)
Link Adapters AL005-(P)E and AL006-(P)E can be connected with crystal opti-
cal fiber cable in accordance with the following specifications:
Item
Specifications
Conforming optical fiber
Graded index 50/125
Applicable wavelength
800-900 nm
Transmit/receive differential
13 dB (min)
The transmission distance between Link Adapters AL005-(P)E and AL006-(P)E
is basically determined by the difference between the transmitting and receiving
levels of the Link Adapters and by the transmission loss over the crystal optical
fiber cable. It is also affected, however, by the number of connecting points and
the method of connection, as well as by the particular type of cable which is
used. Use the calculation method shown below to determine whether a given
cable length will fall within tolerable limits.