Table 2-1 details the available gain settings and resulting input ranges for the various
input configurations. Note that the 'gain byte' field in Table 2-1 is the value written to the
DAQ-12's gain control register. (* indicates unipolar mode not available with gain of

½ ).

83

2-3

4

+2.5/ ±1.25

82

2-3

2

+5/ ±2.5

81

2-3

1

+10/ ±5

80

2-3

½

N/A*/ ±10

03

2-3

250

+0.04/±0.02

02

2-3

50

+0.2/±0.1

01

2-3

5

+2/±1

00

2-3

½

N/A*/±10

83

1-2

8

+1.25/±0.625

82

1-2

4

+2.5/±1.25

81

1-2

2

+5/±2.5

80

1-2

1

+10/±5

03

1-2

500

+0.02/±0.01

02

1-2

100

+0.1/±0.05

01

1-2

10

+1/±0.5

00

1-2

1

+10/±5

---

---

Gain

Unipolar / Bipolar

Gain Byte (HEX)

J7

Amplifier

Maximum Input Voltage

Table 2-1. Recommended Input Ranges and Gain Settings