Troubleshooting Guide

7-1

7

7.1 Display Error Messages

Error Message

Problem

Solution

CAL OVERFLOW!

While calibrating, you

1.

Repeatedly press the

have allowed the motor

CALIBRATE key until

to run at a high RPM

the message “Prime or

setting for a very long

START?” appears.

time, or you have entered
a total volume that would
result in an inappropriate
calibration factor.

Calibration FAIL

Your attempt to calibrate

1.

Repeatedly press the

was unsuccessful.

CALIBRATE key until
the message “Prime or
START?” appears.

2.

Repeat calibration but only
allow the motor to run for a
minute or two.
NOTE: Make sure that you
measure the volume of the
dispensed fluid accurately.

Illegal Op Code

A

A

The line voltage may

1.

Use a multimeter to measure

be bad.

the line voltage used by the
pump motor.

2.

Compare the voltage rating
on the unit’s label (on the back
of the pump motor) with the
line voltage to make sure that
you are using the correct volt-
age. The pump motor
requires line voltages of 90 to
130 Vac (for 115 Vac units)
or 190 to 260 Vac (for 220
Vac units).

2. Repeat calibration but only

allow the pump to run for a
minute or two. NOTE: Make
sure that you measure the
volume of the dispensed fluid
accurately.