beautypg.com

3 stacking two pumps on one side of the motor – Omega Vehicle Security FPU5-MT-110 User Manual

Page 22

background image

5.

Refer to Figure 3-4. With the pump and motor aligned, insert the mounting
screws through the mounting holes in the pump, until they make contact with the
threaded mounting holes in the face of the motor.

6.

Tighten the screws fully with a 9/64 (M3.5) allen wrench.

3.1.3 Stacking Two Pumps on One Side of the Motor

Perform ALL of the steps in Chapter 3 before turning the motor on.

Figure 3-5. Placing the Second Pump

Figure 3-6. Aligning the Rotor Shaft

Figure 3-7. Securing Both Pumps to

on Top of the First Pump

of the Second Pump

the Motor

1.

Remove the safety cover if it is on the side of the motor you wish to use. Attach
it to the other side.

2.

Refer to Figure 3-1 through Figure 3-3. Perform Steps 1, 2 and 3 in Section
3.1.2 to put the first pump on the face of the motor.

3.

Refer to Figure 3-1. Make sure the second pump is in the closed position.

4.

Refer to Figure 3-5 and Figure 3-6. Place the blade of the flathead screwdriver
in the groove of the Rotor Shaft of the second pump. Rotate the Rotor Shaft of
the second pump until its back tab slips into the groove of the Rotor Shaft of the
first pump.

5.

Refer to Figure 3-7. With the pumps and motor aligned, insert the optional
LONG mounting screws through the mounting holes in both pumps, until they
make contact with the threaded mounting holes in the motor.

6.

Tighten the long screws fully with a small flathead screwdriver.

LONG
MOUNTING
SCREWS

FACE OF
MOTOR

FLAT HEAD
SCREWDRIVER

FIRST PUMP

SECOND
PUMP

FACE OF
MOTOR

FIRST
PUMP

SECOND
PUMP

Getting Started

3

3-3

CAUTION