beautypg.com

Omega Speaker Systems PCI-DAS1001 User Manual

Page 37

background image

8.4 COUNTER SECTION

Counter type

82C54

Configuration

Two 82C54 devices. 3 down counters per 82C54, 16 bits each

82C54A:

Counter 0 - ADC residual sample counter.

Source:

ADC Clock.

Gate:

Internal programmable source.

Output: End-of-Acquisition

interrupt.

Counter 1 - ADC Pacer Lower Divider

Source:

10 MHz oscillator

Gate:

Tied to Counter 2 gate, programmable source.

Output:

Chained to Counter 2 Clock.

Counter 2 - ADC Pacer Upper Divider

Source:

Counter 1 Output.

Gate:

Tied to Counter 1 gate, programmable source.

Output:

ADC Pacer clock (if software selected), available at connector

82C54B:

Counter 0 - Pretrigger Mode

Source:

ADC Clock.

Gate:

External trigger

Output:

End-of-Acquisition interrupt.

Counter 0 - User Counter 4 (when in non-Pretrigger Mode)

Source:

User input at 100pin connector (CLK4) or internal 10MHz
(software selectable)

Gate:

User input at 100pin connector (GATE4).

Output:

Available at 100pin connector (OUT4).

Counter 1 - User Counter 5

Source:

User input at 100pin connector (CLK5).

Gate:

User input at 100pin connector (GATE5).

Output:

Available at 100pin connector (OUT5).

Counter 2 - User Counter 6

Source:

User input at 100pin connector (CLK6).

Gate:

User input at 100pin connector (GATE6).

Output:

Available at 100pin connector (OUT6).

Clock input frequency

10Mhz max

High pulse width (clock input)

30ns min

Low pulse width (clock input)

50ns min

Gate width high or low

50ns min

Input low voltage

0.8V max

Input high voltage

2.0V min

Output low voltage

0.4V max

Output high voltage

3.0V min

8.5 OTHER SPECIFICATIONS

Power consumption

+5V Operating (A/D converting to FIFO)

0.8A typical, 1.0A max

Environmental

Operating temperature range

0 to 70°C

Storage temperature range

-40 to 100°C

Humidity

0 to 90% non-condensing

34