6. External Dimensions and Sample Foot Pattern of M32170T-PTC

Figure 4 External dimensions and sample foot pattern of M32170T-PTC

5. Connection Procedure

The procedure for connecting the M32170T-PTC is shown
below.

(1) Mount the NQPACK240SD.

(2) Mount the YQPACK240SD on the NQPACK240SD.

(3) Secure the four corners of the YQPACK240SD with the

YQ-GUIDE's.

(4) Set the clock select switch.

EXT*

1

:

Supplies the clock of the XIN pin of the target
board to the MCU on the M32170T-PTC
board.

INT:

Supplies the clock (10 MHz) on the M32170T-
PTC board to the MCU.

(5) Connect the probe of the emulation pod and the M32170T-

PTC via the SDI MCU control interface cable and the
SDI trace interface cable.

(6) Mount the M32170T-PTC on the YQPACK240SD.

*1 When setting to "EXT", make note of the fact that the

oscillation by the oscillator on the target board does not
occur. Connect the output of the oscillator etc. to the XIN
pin.