Connection procedure, External dimensions and a sample foot pattern, Connection procedure (see figure 3) – Renesas R0E521134CFG00 User Manual
Page 5
(3/4)
5. Connection Procedure (See Figure 3)
The procedure for connecting the R0E521134CFG00 is shown
below.
(1) Mount the NQPACK032SA on the user system.
(2) Attach the YQPACK032SA on the NQPACK032SA.
(3) Secure the four corners of the YQPACK032SA with the
YQ-GUIDE's.
● Do not use the screws included with the
YQPACK032SA for fixing the YQPACK032SA.
● The screwdriver included with the NQPACK032SA is
used for fixing the HQPACK032SA. Do not use it for
fixing the YQ-GUIDE’s.
(4) Attach the R0E521000EPB00 or R0E521000CPE00 to the
R0E521134CFG00.
(5) Attach the R0E521134CFG00 to the YQPACK032SA.
32- pin 0.8- mm- pitch
(PLQP0032GB-A) foot pattern
YQ- GUIDE (x4)
YQPACK032 SA
NQPACK032SA
(1)
(2)
(4)
(5)
R0E521134CFG00
(3)
R0E 521000 EPB00
or
R0E 521000CPE00
Be sure to use a
flathead screwdriver.
Figure 3 Connection procedure of the R0E521134CFG00
6. External Dimensions and a Sample Foot Pattern (See Figure 4)
Figure 4 External dimensions and a sample foot pattern of the R0E521134CFG00
28.5
16.5
32.0
0.5
0.8
6.8
10.0
6.
8
10
.0
Unit: mm