3. Attach the sleeve
Attach to the inside wall using 3 screws arranging
the flange so that the marking “TOP” is at the top.
The flange is offset 2° to allow the condensate to
drain to the outside.
Flue Manifold Installation
4. Install the Terminal
Check that the terminal seal is in place. For 
weatherboard or vinyl siding, add the second seal 
next to the terminal seal to compensate for the 
angle. 
From the outside insert the terminal into the 
sleeve with the marking “TOP” at the top. The left 
hand side locking tie should be marked “LEFT”. 
5. Lock the ties
Pulling hard on the left and right hand ties, clip 
the ties over the notches inside the sleeve. You 
should be able to pull the ties 2 or 3 notches past 
the starting point. Cut the ties, leaving about 3/4 
inch (20 mm) past the notch. Bend the ties back 
into the sleeve and parallel to the wall. 
6. Attach Inside Connection Assembly
Push the assembly into the terminal tube.
Attach the inside connection with 3 screws. The 
inside connection can still be turned if necessary. 
3 screws
sleeve should extend 
3/16 - 3/8 in (5-10 mm) 
Locking tie
Terminal
Locking ties
Sleeve
Terminal seal