Fault
Codes
If there is a malfunction the appliance may shut down as a safety precaution and display a fault code to assist in
diagnosing the problem. The fault code will flash in the Fault Code Display window and the Operation Indicator
will flash green.
Code
Fault
Remedy
11 Ignition
failure
Confirm that the gas supply is turned on. Switch appliance to
STANDBY and then ON again. If ignition failure continues
then a Service call is required.
12 Incomplete
combustion
Service
call
14
Filter blocked or Overheat
Clean filters
If overheating continues then a service call is required to
determine the cause.
Thermal fuse; a qualified service technician must replace the
fuse following the procedure below.
16 Room
overheat
The temperature has reached 104° F (40° C). Turn the
appliance off or engage the AUTO OFF function to prevent the
display of flame. See AUTO OFF section.
31
Room temperature sensor faulty
Service call
32
Overheat temperature sensor faulty
Service call
53
Spark sensor faulty Service
call
61
Fan motor faulty
Service call
71 Solenoids
faulty
Service
call
72
Flame detection circuit fault
Service call
73 Communication
fault
Service
call
99
Flue block
Check around flue terminal for obstructions to air flow
The cause of the overheat condition needs to be
determined and remedied before replacing the
thermal fuse.
A qualified service technician needs to:
1. Disconnect the appliance from the power supply.
2. Remove the right hand side panel to allow access
to the gas control and main PCB.
3. Unplug the thermal fuse harness (including the
control plug for the POV on the gas control) and
unscrew thermal fuse.
4. Re-assemble with replacement thermal fuse.
PCB
POV
Thermal Fuse
Replacement of Thermal Fuse