beautypg.com

Ricoh GigE Vision VGA Monochrome CCD Camera FV-G030B1 User Manual

Page 33

background image



33/37

FV-G030B1
User’s Guide Rev. 1.01

Command No.

Command Description

50H: [7..0]

51H: [15..8]

[Y_offset for AOI]

Initial data: 0, data range: 2 ≤ “Y_offset + Height” ≤ 494

Sets the Y_offset (the vertical start position of the image for the AOI)

52H: [7..0]

53H: [15..8]

[Height for AOI]

Initial data: 494, data range: 2 ≤ “Y_offset + Height” ≤ 494

Sets the height (the vertical size of the image for the AOI)

54H: [7..0]

55H: [15..8]

[X_offset for AOI]

Initial data: 0, data range: 8 ≤ “Y_offset + Height” ≤ 648

Sets the X_offset (the horizontal start position of the image for the AOI)

56H: [7..0]

57H: [15..8]

[Width for AOI]

Initial data: 648, data range: 8 ≤ “Y_offset + Height” ≤ 648

Sets the width (the horizontal size of the image for the AOI)

60H: [7..0]

[Camera mode 1] Initial data: 00H

Sets the white balance area ON/OFF and the gamma table ON/OFF.

D[7..0]

D7

D6

D5

D4

D3

D2

D1

D0

D7 to D5:

No function

Always set at “000”

D4:

White balance area ON/OFF

0: OFF (Full screen)

1: ON (setup area)

D3 to D1:

No function

Always set as “000”

D0:

Gamma table ON/OFF

0: OFF (Gamma=1.0)

1: ON

92H: [7..0]

[Iris lens manual adjustment] Initial data: 01H

Sets the iris lens manual adjustment operation.

D[7..0]

D7

D6

D5

D4

D3

D2

D1

D0

D7 to D2:

No function

Always set as “000000”

D1 to D0:

Manual adjustment operation

00: Hold

01: Open

10: Close

11: No Function (Prohibited setting. Do not set this value)