beautypg.com

Testing and commissioning – Rinnai FS35ETRSN/US User Manual

Page 16

background image

16

TESTING PROCEDURE

Turn gas supply on and plug the unit into
the power supply. (Caution 115V)

TO CHECK BURNER PRESSURE

• Refer to rating plate.

• Remove the wiring cover panel.

• Remove test point plug and attach

manometer to test point.

The test point is on the bottom front face

of the gas valve.

• Light heater, turn to High heat setting and

check pressure.

• If adjustments are necessary, the

regulator is situated on the front of the
gas control.

• After checking pressure, turn the unit off,

remove manometer and replace test
point plug.

• Turn the heater on and off a few times to

check ignition.

• When you are satisfied that the heater is

working correctly, reassemble panels.

• All burner aeration is factory preset and

cannot be adjusted.

• If you are unable to get the unit to operate

correctly, refer to Troubleshooting on
Page 20, before contacting your local
service contact as listed on Page 3.

• It may take approximately 2 hours for the

logs to achieve their full flame pattern
and glow.

During the initial burning in period,

some smoke and smell may be
experienced. The heater should be
run on the high position in a well
ventilated room until these
dissipate.

TESTING AND COMMISSIONING

It is the responsibility of the installer
to check that under normal operating
conditions of the appliance, all flue
gases are exhausted to the outside
atmosphere and that there is no
spillage of combustion gases into the
room.

COMMISSIONING

INSTALLATION / COMMISSIONING
CHECKLIST

Complete the installation checklist and the
installer details on page 27 and make sure
that this instruction book is left with the
customer.

INSTRUCT CUSTOMER ON USE OF
UNIT

Explain to the customer about use and care
of unit. Make sure the customer
understands the instructions.

EXPLAIN

Ignition (on / off), adjusting heat level,
programming timers, flame setting, auto
off, lock, override and the remote control.

NOTE:

THE MANUFACTURE RESERVES THE
RIGHT TO CHANGE OR MODIFY
SPECIFICATIONS WITHOUT NOTICE

This manual is related to the following products: