beautypg.com

E table 3-1, Table 3-1. if, Ee table 3-2 – Raymarine 150/400 User Manual

Page 24

background image

16

Type 150/400 Autopilot System: Installation Guide

Ste

p

3

* These specifications apply to the cabling for CR pump solenoids. Power the
CR pump motor separately, as specified in the CR pump installation guide.

Table 3-1: Recommended power supply cable sizes (stranded cables)

Cable length
(distribution panel to course computer)

Cable gauge
(AWG)

Copper area
(mm

2

)

Type 1 drive 12/24 V;
I/O drive; CR pump solenoids*

up to 3m (10ft)
up to 5m (16ft)
up to 7m (23ft)
up to 10m (32ft)
up to 16m (52ft)

14 AWG
12 AWG
10 AWG
8 AWG
6 AWG

2.5 mm

2

4 mm

2

6 mm

2

10 mm

2

16 mm

2

Type 2 drive 12 V

up to 5m (16ft)
up to 7m (23ft)
up to 16m (52ft)

10 AWG
8 AWG
6 AWG

6 mm

2

10 mm

2

16 mm

2

Type 2 drive 24 V

up to 3m (10ft)
up to 5m (16ft)
up to 10m (32ft)
up to 16m (52ft)

12 AWG
10 AWG
8 AWG
6 AWG

4 mm

2

6 mm

2

10 mm

2

16 mm

2

Type 3 drive 12 V

up to 5m (16ft)
up to 7m (23ft)
up to 16m (52ft)

8 AWG
6 AWG
4 AWG

10 mm

2

16 mm

2

25 mm

2

Type 3 drive 24 V

up to 5m (16ft)
up to 7m (23ft)
up to 16m (52ft)

10 AWG
8 AWG
6 AWG

6 mm

2

10 mm

2

16 mm

2

Table 3-2: Recommended power cable fuse and circuit breaker sizes

Drive unit

Fuse (Amps)

Thermal over-current
circuit breaker
(Amps)

Rotary, linear, hydraulic pump,
hydraulic linear

Type 1: 12 V and 24 V
Type 2: 12 V
Type 2: 24 V
Type 3: 12 V and 24 V

25 A
40 A
30 A
40 A

20 A
30 A
30 A
30 A

I/O drive

15 A

10 A

CR pump solenoids*

10 A

10 A

81173_3.book Page 16 Thursday, June 7, 2001 11:51 AM