5

TOOLS NEEDED

The following information will indicate some tools and
materials necessary for a complete installation:

• 4 twisted pair communication wire (commonly referred to

as CAT-5). This wire will be used to connect the keypads
in each zone to the controller. 16 Gauge minimum, 2
conductor CL3 rated wire. (Russound AW162CL3) This
wire is used for direct connection between the CA and
your speakers.

• 110 Punchdown tool (included)

• A small jewelers flat-head screwdriver (included)

• A medium sized flat-head screwdriver.

• Wire strippers and cutters

• Electric drill and a 1/2" x 6" drill bit

• A steel-wire fish tape

• A keyhole saw

• Electrical junction boxes (6)

• A stud finder

• A screwdriver (cordless recommended)

• Misc. hand tools, nails & screws

• Cable staples

If you have problems or you are not absolutely comfortable
with what you are doing, consult a professional carpenter,
electrician, or system installer.

BASIC PLANNING AND LAYOUT CONSIDERATIONS

• Where will the speakers be located?

• Where will the keypads be located?

• How will the wiring be routed to each location?

• Where is the source equipment located?

• Where is the CA controller going to be located?

CONNECTION TIPS

• Disconnect all power cords before connecting to the CA.

• Verify that all connections and polarity are correct.

• Keep all power cords away from all signal cables to pre-

vent noise or humming.

• Choose reliable signal cables / patch cords.

• Label all wires with room location at both ends of the

wire.

• Take your time!!! Don't panic about the number of wires;

simply connect one at a time.

G

ETTING

S

TARTED

Speaker Wire Length

Gauge of Speaker Wire

10-100 feet

16 AWG

100-150 feet

14 AWG

Over 150 feet

12 AWG

Keypad Control Max

Recommended

Wire Type

Wire Length

CAT-5

100 feet

Russound MCW2418

200 feet

CA-Series manual R6 10/17/01 1:50 PM Page 5