Troubleshooting

TROUBLE

PROBABLE CAUSE

REMEDY

Excessive noise
(knocking)

Continued

Oil in the discharge
air

5. Worn bearings

6. Piston hitting the valve

plate

7. Noisy check valve

1. Worn piston rings
2. Compressor air intake

restricted

3. Restricted breather

4. Excessive oil in compres-

sor

5. Wrong oil viscosity

6. Connecting rod out of

alignment

5. Replace worn bearings

and change oil

6. Remove the compressor

head and valve plate and
inspect for carbon deposits
or other foreign matter on
top of piston. Replace head
and valve plate using new
gasket

7. Replace

1. Replace with new rings
2. Clean filter. Check for other

restrictions in the intake
system

3. Clean and check breather

for free operation

4. Drain down to full level

5. Use SAE 30 (ISO 100)

non-detergent compressor
oil

6. Replace rod