U37-1 Regency

®

ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove

IMPORTANT MESSAGE

SAVE THESE

INSTRUCTIONS

The ULTIMATE Rear Vent Direct Vent Freestand-
ing Gas Stove must be installed in accordance
with these instructions. Carefully read all the
instructions in this manual fi rst. Consult the
building authority having jurisdiction to deter-
mine the need for a permit prior to starting the
installation.

Note: Failure to follow the instructions

could cause a malfunction of the
heater which could result in death,
serious bodily injury, and/or prop-
erty damage. Failure to follow these
instructions may also void your fi re
insurance and/or warranty.

SPECIFICATIONS

Fuels:

U37-NG1 is approved for use with
natural gas.

U37-LP1 is approved for use with liq-
uefi ed petroleum gases (propane).

Electrical: 120 V A.C. system.

Circulation Fan: Variable speed, 125/75.

Log Sets: Ceramic fi bre, 7 per set.

Vent System:

Axial (6-5/8" outer / 4" inner liner) rigid
fl ue and Riser Vent Terminal.

BEFORE YOU START

Safe installation and operation of this appli-
ance requires common sense, however, we
are required by the Canadian Safety Standards
and ANSI Standards to make you aware of the
following:

INSTALLATION

into a manufactured home the unit must be

bolted down to the fl oor.

4) We recommend that you plan your instal-

lation on paper using exact measurements

for clearances and fl oor protection before

actually installing this appliance. Have a

qualifi ed building inspector review your plans

before installation.

GENERAL SAFETY

INFORMATION

1) The

appliance

installation

must

conform

with

local Canadian Electrical Code.

2) The appliance when installed, must be

electrically grounded in accordance with
local codes, or in the absence of local codes
with the current National Electrical Code,
ANSI/NFPA 70 or CSA C22.1 Canadian
Electrical Code.

3) The appliance should be inspected for

shipping damage before use and serv-
iced annually by a professional service
person
. More frequent cleaning may be
required due to excessive lint from carpet-
ing, bedding material, etc. It is imperative
that control compartments, and circulating
air passageways of the appliance be kept
clean and free from excessive lint from
carpeting.

4) See general construction and assembly

instructions. The appliance and vent should
be enclosed when installed in or passing
through a living area, where children may
come in contact with it.

5) This appliance must be connected to the

specifi ed vent and termination cap to the
outside of the building envelope. Never vent
to another room or inside a building. Make
sure that the vent is fi tted as per the instruc-
tions starting in the "Venting" section.

6) Inspect the venting system annually for

blockage and any signs of deterioration.

7) Venting terminals shall not be recessed into

a wall or siding.

8) Any safety glass removed for servicing

must be replaced prior to operating the ap-
pliance.

9) To prevent injury, do not allow anyone who

is unfamiliar with the operation to use the
fi replace.

1) Provide adequate clearances for servicing,

proper operation and around the air openings

into the combustion chamber.

2) The appliance must be installed on a fl at,

solid, continuous surface (e.g. wood, metal,

concrete). This may be the fl oor, or it can be

raised up on a platform to enhance its visual

impact. The appliance may be installed on

carpeting, tile, wood fl ooring or other com-

bustible material, because the appliance's

metal pedestal base extends the full width

and depth of the appliance. The ULTIMATE

Rear Vent Direct Vent Freestanding Gas

Stove can be installed in a wide variety of

ways and will fi t nearly any room layout.

It may be installed in a recessed position,

framed out into the room, or across a cor-

ner.

3) The ULTIMATE Rear Vent Direct Vent

Freestanding Gas Stove is approved for

manufactured home installations, see

"Clearances to Combustible" to "Rigid Pipe

Venting - Vertical Terminations" section for

the required vent arrangements. If installed

Emissions from burning wood or gas could
contain chemicals known to the State of Cali-
fornia to cause cancer, birth defects or other
reproductive harm.

DUE TO HIGH TEMPERATURES,
THE APPLIANCE SHOULD BE
LOCATED OUT OF TRAFFIC AND
AWAY FROM FURNITURE AND
DRAPERIES.

WARNING: FAILURE TO INSTALL
THIS APPLIANCE CORRECTLY
WILL VOID YOUR WARRANTY AND
MAY CAUSE A SERIOUS HOUSE
FIRE.

CHILDREN AND ADULTS SHOULD
BE ALERTED TO THE HAZARDS
OF HIGH SURFACE TEMPERA-
TURES, ESPECIALLY THE FIRE-
PLACE GLASS, AND SHOULD
STAY AWAY TO AVOID BURNS OR
CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE
CAREFULLY SUPERVISED WHEN
THEY ARE IN THE SAME ROOM AS
THE APPLIANCE.

CLOTHING OR OTHER FLAM-
MABLE MATERIAL SHOULD NOT
BE PLACED ON OR NEAR THE
APPLIANCE.

INSTALLATION AND REPAIRS
SHOULD BE DONE BY A QUALI-
FIED SERVICE PERSON. THIS AP-
PLIANCE SHOULD BE INSTALLED,
REPAIRED, INSPECTED BEFORE
USE AND AT LEAST ANNUALLY
BY A QUALIFIED SERVICE PER-
SON. MORE FREQUENT CLEAN-
ING MAY BE REQUIRED DUE TO
EXCESSIVE LINT FROM CARPET-
ING, ETC. IT IS IMPERATIVE THAT
THE CONTROL COMPARTMENT,
BURNERS AND CIRCULATING AIR
PASSAGEWAYS OF THE APPLI-
ANCE BE KEPT CLEAN.