beautypg.com

Installation – Regency ULTIMATE U37-LP1 User Manual

Page 19

background image

U37-1 Regency

®

ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove

19

15) Verify that if the conversion is from NG

to LPG, the screw must be re-assem-
bled with the red o-ring visible (Fig. 5).

LPG Configuration

Red o-ring visible

Fig.5

16) Re-assemble the black protection cap

(Fig. 6).

Fig. 6

WARNING!

Also check that the pilot and main

burner injectors are appropriate for

the gas type.

18) Attach the label "This unit has been

converted to LPG" near or on top of the
serial # decal.

19) Replace yellow "NG" label with red

"LPG" label.

17) Reverse

steps

4

-

1.

Fig.2

13) Flip the screw (Fig. 3).

Fig.4

Fig.3

14) Using the Allen wrench

as shown in Fig.4, rotate
the screw clockwise until
snug, do not overtighten.

11) Insert a 5/32” or 4mm

Allen wrench into the
hexagonal key-way
of the screw (Fig.
2), rotate it counter-
clockwise until it is free
and extract it.

12) Check that the screw is clean and if

necessary remove dirt.

WARNING!

Do not over tighten the screw.

Recommended to

grip the wrench by the short side.

20) Check for gas leaks.

21) Check inlet and outlet pressures.

22) Check operation of fl ame control.

23) Check for proper fl ame appearance and

glow on logs.

Fig. 1

10) Remove

the

black

protection cap by hand
from the hi-low knob
(Fig.1).

9)

Pull off the Hi/Lo gas extension knob to
access the orifi ce.

INSTALLATION

This manual is related to the following products: