40

DIP SWITCH SETTING

Dip Switch Positions Explained

OFF ON SW

1 -

Gas

Type

LEGEND:

2

- Gas Type

Black Section indicates

3

- Computer Programming

position of dip switch.

4

- Computer Programming

5 -

Computer

Programming

OFF ON

OFF ON

6 -

Max.

Temperature

7 -

Combustion

OFF ON

8 -

Combustion

Dip Switches Explained

GAS TYPE

COMBUSTION

LPG

NAT GAS

NORMAL

OFF ON SW

OFF ON SW

OFF ON SW

1 off

1 on

7 off

2 off

2 off

8 off

FORCED LOW

COMPUTER PROGRAMMING

OFF ON SW

7 on

OFF ON SW

8 off

1

Computer

programming

2

Switches (3-5) must be left

FORCED HIGH

3

in the factory set position

4

for the Infinity 16i.

OFF ON SW

5

7 on

6

8 on

7

8

MAXIMUM TEMPERATURE

OFF ON

6 Maximum Temperature = 60

0

C

6 Maximum Temperature = 75

0

C