beautypg.com

Royal Sovereign 451-8 24B/9L RSL-2702S User Manual

Page 7

background image

3. Defective heater.

a. Test continuity of the heater. If it fails, replace the heater.

b. Glass tube that surrounds heating coil is broken – replace the heating element.

a. Replace the PCB Main.

2.3) Rollers Not Running

1. No power to the unit.

2. Emergency switch is engaged.

3. Opened safety cover.

4.Opened Front Table Switch.

5. Film is jammed on the rollers.

6. Disconnected motor wire.

7. Blown motor fuse.

8. Defective main motor.

9. Defective main PCB.

1. No power to the unit.

a. Make sure the power plug is connected to the proper source of outlet

(220V, 15Amp, & single phase).

2. Emergency switch is engaged.

5

4. Defective Main PCB.

CAUSES

MEASURES

Switch is engaged