beautypg.com

Royal Sovereign 451-8 24B/9L RSL-2702S User Manual

Page 6

background image

a. Replace the PCB Main.

2.2) Rollers Over Heating

1. Lower and upper heat sensors are reversed on the PCB Main.

1. Wires for lower and upper heat sensors are reversed on the main PCB.

a. Reverse the heat sensors.

a. Replace the T/Fuse wire located on the left-hand side.

2. Defective T/Fuse wire.

4

4. Defective main PCB.

MEASURES

6. Defective Main PCB.

CAUSES

2. Defective T/Fuse wire.

3. Defective heater.

Connector-Wire Sensor

WIRE-LO-T/ FUSE

WIRE-UP-T/FUSE

This manual is related to the following products: