BURNER PRESSURE ADJUSTMENT

34

Hi/Lo Models

To adjust the burner pressure on a water heater with a White Rodgers 36E20 Type 301 Hi/Lo gas control, proceed
as follows:

109 Hi/Lo Models

• Remove the screw and washer from the burner feed pipe pressure tap.
• Attach a manometer to the pressure tap.
• Remove the 20mm plug from the left hand side of the water heater

and remove the cap from the high fire pressure regulator adjuster.

• With the main burner operating on high fire, adjust the pressure

regulator (clockwise to increase or anti-clockwise to decrease) to
achieve the burner pressure as specified on the rating label (refer to
“Location of Controls” on page 29).

NOTE

: To ensure the burner is operating at high fire it may be

necessary to increase set point on the thermostat (refer to
“Temperature Control” on page 35).

• Remove the cap from the low fire pressure regulator adjuster.
• With the main burner operating on low fire, adjust the pressure regulator

(clockwise to increase or anti-clockwise to decrease) to achieve the burner
pressure as specified on the rating label (refer to “Location of Controls” on
page 29).

NOTE

: To ensure the burner is operating on low fire it may be necessary to

decrease the set point on the thermostat (refer to “Temperature Control” on
page 35).

• Turn off the water heater.
• Replace the caps on the pressure regulator adjusters and the 20 mm plug in the left hand side panel.
• Disconnect the manometer and replace the pressure tap screw and washer.
• Check for gas leaks, using soapy water.

147 Hi/Lo Models

• Remove the screw and washer from the outlet pressure tap.
• Attach a manometer to the outlet pressure tap.
• Remove the cap from the high fire pressure regulator adjuster.
• With the main burner operating on high fire, adjust the pressure

regulator (clockwise to increase or anti-clockwise to decrease) to
achieve the burner pressure as specified on the rating label (refer to
“Location of Controls” on page 29).

NOTE

: To ensure the burner is operating at high fire it may be

necessary to increase set point “SE.1” on the thermostat (refer to
“Temperature Control” on page 36).

• Remove the cap from the low fire pressure regulator adjuster.
• With the main burner operating on low fire, adjust the pressure

regulator (clockwise to increase or anti-clockwise to decrease) to
achieve the burner pressure as specified on the rating label (refer to
“Location of Controls” on page 29).

NOTE

: To ensure the burner is operating on low fire it may be necessary to decrease the set point of “SE.2” on

the thermostat (refer to “Temperature Control” on page 36).

• Turn off the water heater.
• Replace the high and low fire caps on the pressure regulator adjusters.
• Disconnect the manometer and replace the pressure tap screw and washer.
• Check for gas leaks, using soapy water.

High fire adjustment

access hole

Regulator Cap

Low fire adjustment

Pressure Tap

Regulator Cap

High fire adjustment

Pressure Tap

Regulator Cap

Low fire adjustment

Regulator Cap

High fire adjustment

This manual is related to the following products: