21

RV5VH1

××

/RV5VH2

××

OPERATION OF STEP-UP DC/DC CONVERTER

Step-up DC/DC Converter charges energy in the inductor when Lx Transistor (LxTr) is on, and discharges the

energy with the addition of the energy from Input Power Source thereto, so that a higher output voltage than the

input voltage is obtained.

The operation will be explained with reference to the following diagrams :

< Current through L >

< Basic Circuits >

i2

L

SD

I

OUT

V

OUT

CL

Lx Tr

i1

V

IN

IL

ILmin

ILmax

topen

t

ton

toff

T=1/fosc

Step 1 : LxTr is turned ON and current IL (=i1 ) flows, so that energy is charged in L. At this moment, IL(=i1 )

is increased from ILmin (=0) to reach ILmax in protection to the on-time period (ton) of LxTr.

Step 2 : When LxTr is turned OFF, Schottky diode (SD) is turned on in order that L maintains IL at ILmax, so that

current IL (=i2) is released.

Step 3 : IL (=i2) is gradually decreased, and IL reaches ILmin (=0) after a time period of topen, so that SD is

turned OFF.

In the case of VFM control system, the output voltage is maintained constant by controlling the oscillator fre-

quency (fosc) with the on-time period (ton) being maintained constant.

In the above two diagrams, the maximum value (ILmax) and the minimum value (ILmin) of the current which

flows through the inductor are the same as those when LxTr is ON and also when LxTr is OFF.

The difference between ILmax and ILmin, which is represented by

I, is:

I=ILmax–ILmin=V

IN

· ton/L=(V

OUT

–V

IN

) · topen/L ..........................................Equation 1

wherein T=1/fosc=ton+toff

duty (%)=ton/T · 100=ton · fosc · 100

topen

toff

In Equation 1,V

IN

· ton/L and (V

OUT

–V

IN

) · topen/L are respectively the change in the current at ON, and the

change in the current at OFF.

In the VFM system, topen < toff as illustrated in the above diagram. In this case, the energy charged in the

inductor during the time period of ton is discharged in its entirely during the time period of toff, so that ILmin