beautypg.com

Rv5vh1, Rv5vh2 – Ricoh RV5VH User Manual

Page 12

background image

RV5VH1

××

/RV5VH2

××

8

Symbol

Item

Conditions

MIN.

TYP.

MAX.

Unit

V

DET

Detector Threshold

2.633

2.700

2.767

V

V

HYS

Detector Threshold Hysteresis

0.081

0.135

0.189

V

I

SS3

Supply Current3

1.2

µA

V

IN

max

Maximum Input Voltage

10

V

V

OPT

min

Minimum Operating Voltage

1.8

V

I

OUT

Output Current

V

DS

=0.5V, V

OUT1

=1.5V

1.0

2.0

mA

V

DS

=0.5V, V

OUT1

=3.0V

4.0

5.0

mA

I

SEN

Sensing pin Input Current

V

SEN

=3.0V

0.3

1.2

µA

V

SEN

Sensing pin Input Voltage

0.7

10

V

t

PLH

Output Delay

100

µs

V

OUT1

Detector Threshold Temp.Co.

–40˚C

Topt

85˚C

±100

ppm/˚C

Topt

I

DOUTleak

D

OUT

Leakage Current

0.03

0.5

µA

V

OUT1

=3.0V, Topt=25˚C

Voltage Detector

*

) V

OUT1

=3.0V, Topt=25˚C, unless otherwise specified. (See Typical Application)