Gas fireplaces, Venting arrangements - horizontal terminations – Regency Panorama P48 User Manual

Page 6

background image

16

2

4

6

8

10

12

14

2

0

0

12

20

6

14

43” (1092mm)
Minimum
Height
Requirement

43” (1092mm)
Minimum
Height
Requirement

4

8

10

18

16

V

ertical

Height

(Feet)

V

ertical

Height

(Feet)

Horizontal (Feet)

Horizontal (Feet)

Venting Arrangements - Horizontal

Terminations

This diagram shows all allowable combinations of vertical runs with
horizontal terminations, using one 45° and one 90° elbow (two 45º

elbows equal one 90° elbow).

Note: Must use optional fl ue adapter (Part # 770-994) when using

Rigid Pipe.

Maintain clearances to combustibles.

Horizontal vent must be supported every 3 feet.

Firestops are required at each fl oor level and whenever passing
through a wall.

A vent guard should be used whenever the termination is lower than the
specifi ed minimum or as per local codes.

Note: FPI Direct Vent System (Flex) is only approved for horizontal

terminations.

Please refer to Page 11 (Exterior Vent Terminations)

for additional guidelines on vent locations.

P48 Gas Fireplace

66

June 2007 Regency Product Specifi cations Book

Gas Fir

eplaces

Gas Fireplaces

This manual is related to the following products: